Two key trends have emerged in the data centre: the demand from today′s IT equipment for more power, & the increasing cost of that power. Couple these with the worldwide growth in demand for data centres & IT servers, & it is clear that data centre managers are facing growing pressure to manage & optimise their available power for growth, at the same time as managing the increasing associated costs. To help them achieve this, they need an accurate view of the power & energy being consumed in the data centre
- from row to rack, & right down to the individual server level. Only then can they truly understand the power usage & optimise the available power.
...
Archived Product
£976.16
Switch & meter outlets & IT equipment across A & B feed: Combines both Switched & Metered Outlet functionality together in 1 e PDUnne PDU G3 Managed models allow complete lights-out control & metering of devices including devices powered across multiple e PDUs. They include IEC Class 1 (&177;1%) billing grade accuracy, an advanced hot-swap meter with LCD pixel display showing V, W, A & k Wh, & the ability to daisy chain 8 e PDUs to share the same network connection & IP address.\n\n\n\n Product ID: EMAB22\n\n\n\n\n\n Model: EMAB22\n\n\n\n\n\n\n\n\n\n\n\n\n\n ...
Available
£976.16
Switch & meter outlets & IT equipment across A & B feed: Combines both Switched & Metered Outlet functionality together in 1 e PDUnne PDU G3 Managed models allow complete lights-out control & metering of devices including devices powered across multiple e PDUs. They include IEC Class 1 (&177;1%) billing grade accuracy, an advanced hot-swap meter with LCD pixel display showing V, W, A & k Wh, & the ability to daisy chain 8 e PDUs to share the same network connection & IP address.\n\n\n\n Product ID: EMAB22\n\n\n\n\n\n Model: EMAB22\n\n\n\n\n\n\n\n\n\n\n\n\n\n ...
Available
£477.09
New e PDU G3 Metered Input models feature best-in-class technologies, including &177;1% billing grade accuracy, an advanced LCD pixel display, a hot-swap meter & the ability to daisy chain four e PDUs to share the same network connection & IP address.\n\n\n\n\n\n\n\n\n\n Model: EMIB05\n\n\n\n\n\n\n\n\n\n\n\n\n\n ...
Available
£477.09
New e PDU G3 Metered Input models feature best-in-class technologies, including &177;1% billing grade accuracy, an advanced LCD pixel display, a hot-swap meter & the ability to daisy chain four e PDUs to share the same network connection & IP address.\n\n\n\n\n\n\n\n\n\n Model: EMIB05\n\n\n\n\n\n\n\n\n\n\n\n\n\n ...
Available
£102.34
The optional Eaton Environmental Monitoring Probe (EMP) Gen 2 is a connectivity device that enables you to collect temperature & humidity readings in rack enclosures & monitor environmental data remotely using Eaton's power monitoring solutions or a standard web browser. Each EMP provides one temperature, one humidity, & two dry-contact status data points. Compatible with UPSs & PDUs, the EMP Gen 2 features a translucent case & integrated LED to positively identify the status of each sensor at a glance while walking the aisles. nn Never lose a second of up timen Monitor for heat, humidity, water, smoke, or door opens.nn Plan ahead in case of extended power failuresn Create customizable shutdown & load shedding protocols.nn Convenient web interfacen Real-time, 24/7 enterprise monitoring with automatic email alarm notifications\n\n\n\n\n\n\n\n\n\n Model: EMPDT1H1C2\n\n\n\n\n\n\n\n\n\n\n\n\n\n ...
Available
£136.84
Designed for reliable & cost effective power distribution, Basic e PDUs have the form factor & outlet choices to meet your needs. All e PDUs, including basic e PDUs, are made from rugged aluminium or steel chassis & incorporate fully shrouded circuit breakers & switches. ...
Archived Product
£10.77
Eaton ETN-OBSP1U. Type: Cable management panel, Product

Colour:
Black, Rack capacity: 1U\n\n\n\n Features

...
Available
£10.77
Eaton ETN-OBSP1U. Type: Cable management panel, Product

Colour:
Black, Rack capacity: 1U\n\n\n\n Features

...
Available
£10.77
Eaton ETN-OBSP1U. Type: Cable management panel, Product

Colour:
Black, Rack capacity: 1U\n\n\n\n Features

...
Available

Eaton EMP001 Temperature/humidity Sensor Indoor Temperature & Humidity
Sensor Freestanding Wired

The optional environmental monitoring probe (EMP) is a connectivity device that enables you to collect temperature and humidity readings in the rack environment and monitor the environmental data remotely via the onboard LCD screen or remotely using a Telnet connection or a standard web browser. You can also collect and retrieve the status of two contact devices.\n\n- When temperature and humidity values exceed user-selectable limits, the event is logged in the ePDU event history log.\n- The EMP monitors temperature and humidity information of any environment that you want to protect your critical equipment. The EMP measures temperatures from 32&176;F to 158&176;F (0&176;C to 70&176;C) with an accuracy of &177;3.6&176;F (&177;2&176;C).\n- The EMP measures relative humidity from 10% to 90%
with an accuracy of &177;5%.\n- It can be located away from the ePDU with a CAT5 network cable up to 65.6 ft (20 m) long.\n- The hot-swap feature simplifies installation by enabling you to install the probe safely without turning off power to the ePDU or to the loads that are connected to it.\n- The EMP monitors the status of the two user-provided contact devices.\n- Temperature, humidity, and contact closure status can be displayed through a web browser, a serial interface, or an onboard LCD interface.\n- User-selectable alarm thresholds enable you to define acceptable temperature or humidity limits.\n- Email notification through Simple Mail Transfer Protocol (SMTP), using email client software when acceptable alarm limits are exceeded or contact status changes.\n- Changes in
external contact status are logged in the ePDU event history log.\n\n\n\nProduct ID: EMP001\n\n\n\n\n\nModel: EMP001\n\n\n\n\n\n\n\n\n\n\n\n\n\n
Availability: In Stock
£93.63

Product Description

The optional environmental monitoring probe (EMP) is a connectivity device that enables you to collect temperature & humidity readings in the rack environment & monitor the environmental data remotely via the onboard LCD screen or remotely using a Telnet connection or a standard web browser. You can also collect & retrieve the status of two contact devices.\n\n- When temperature & humidity values exceed user-selectable limits, the event is logged in the e PDU event history log.\n- The EMP monitors temperature & humidity information of any environment that you want to protect your critical equipment. The EMP measures temperatures from 32&176;F to 158&176;F (0&176;C to 70&176;C) with an accuracy of &177;3.6&176;F (&177;2&176;C).\n- The EMP measures relative humidity from 10% to 90% with an accuracy of &177;5%.\n- It can be located away from the e PDU with a CAT5 network cable up to 65.6 ft (20 m) long.\n- The hot-swap feature simplifies installation by enabling you to install the probe safely without turning off power to the e PDU or to the loads that are connected to it.\n- The EMP monitors the status of the two user-provided contact devices.\n- Temperature, humidity, & contact closure status can be displayed through a web browser, a serial interface, or an onboard LCD interface.\n- User-selectable alarm thresholds enable you to define acceptable temperature or humidity limits.\n- Email notification through Simple Mail Transfer Protocol (SMTP), using email client software when acceptable alarm limits are exceeded or contact status changes.\n- Changes in external contact status are logged in the e PDU event history log.\n\n\n\n Product ID: EMP001\n\n\n\n\n\n Model: EMP001\n\n\n\n\n\n\n\n\n\n\n\n\n\n

Reviews/Comments

Add New

Price History

Oooops!
We couldn't find any historical pricing!

Vouchers

No voucher codes found.
Do you know a voucher code for this product or supplier? Add it to Insights for others to use.

Facebook

Jargon Buster

LCD - Liquid Crystal Display
Alarm - A device which emits a sound at a pre-set time/event
hot - An indication of the temperature being high and a sensation of heat to the tough
email - An electronic communication method. Short for Electronic Mail.
Cable - A series of wires bonded to form a single thread
Mail - Or post is a service for transmitting physical objects or letters between locations
History - Anything that happens in the past. An acedemic subject.
Network - A link and communication between things. Often computers or people.
Equipment - A product or good that is tactile.
Install - A process of putting materials together to create a finished product.
Simple - Basic, easy no difficulty in understanding.
Feature - An attribute that makes something stand out.
Environment - The conditions and surrounding area.

Supplier Information

Transparent Communications
We are a provider of IT and networking equipment at competitive prices with friendly and knowledgeable customer service. Our products include PCs, laptops, tablets, routers, network storage and CCTV, including top brands such as HP, Cisco and Apple.