Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS power overload or fault. Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power. ECO Mode Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection. Input power factor correction Minimizes installation costs by enabling the use of smaller generators & cabling. Intelligent battery management Maximizes battery performance, life, & reliability through intelligent, precision charging. LCD display Alpha-Numeric Display which displays system parameters & alarms. Serial connectivity Provides management of the UPS via a serial port. USB (Universal Serial Bus) connectivity Provides management of the UPS via a USB (Universal Serial Bus) port (not available on all models). Features Management Software means that you can easily monitor your utility power & manage your UPS. ECO Mode Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection. Input power factor correction Minimizes installation costs by enabling the use of smaller generators & cabling. High efficiency High efficiency rates that remain stable even at lower operating power levels. Smart Slot Customize UPS capabilities with management cards. Intuitive LCD interface Provides clear & accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys. Double conversion on-line topology Guarantees a consistently high level of power quality. Any disturbances on the distribution waveform are regenerated via the zero transfer time AC to DC then DC to AC conversion process. The battery is only used as a back-up source. Generator compatible Ensures clean, uninterrupted power to protected equipment when generator power is used. Wide input voltage range Designed for harsh electrical environments to save battery life. Serviceability Disconnected battery notification Warns when a battery is not available to provide backup power. Audible alarms Provides notification of changing utility power & UPS power conditions. Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. Predicitive failure notification Provides early-warning fault analysis ensuring proactive component replacement. Manageability Serial connectivity Provides management of the UPS via a serial port. Smart Slot Customize UPS capabilities with management cards. LCD graphics display Text & mimic diagrams that display modes of operation, system parameters & alarms. Network manageable Provides remote power management of the UPS over the network. LED Indicators Provide easy-to-read status of the unit & utility power conditions. Availability Intelligent battery management Maximizes battery performance, life, & reliability through intelligent, precision charging.\n\n\n\n Power Output voltage regulation 1% Output power factor 0.8 Input power factor 0.95 Output power 800 WInput operation voltage (min)160 VInput operation voltage (max)280 VOutput operation voltage (min)220 VOutput operation voltage (max)240 VSurge energy rating 600 JEfficiency 88% Emergency Power Off (EPO) No Output voltage Total Harmonic Distortion (THD)3% Crest factor 3:1 Output power capacity 1 k VAECO mode Yes Ports & interfaces Socket circuit breaker Yes USB port Yes Serial interface Yes Smart Slot Yes AC outlets quantity 3 AC outlet (s)AC outlet types C13 coupler Power plug C14 coupler Serial ports quantity 1USB port type USB Type-BPerformance Audible alarm modes Alarm when on battery, Fault, Low battery alarm, Overload alarm UPS topology Double-conversion (Online) Waveform Sine Auto-restart Yes Number of output phases 1 Number of input phases 1LED indicators Yes Noise level 50 d B Audible alarm (s) Yes Maintenance-free Yes Features Output frequency 50/60 Hz Audible alarm modes Alarm when on battery, Fault, Low battery alarm, Overload alarm UPS topology Double-conversion (Online) Waveform Sine Output voltage regulation 1% Auto-restart Yes Number of output phases 1 Number of input phases 1 Output power factor 0.8 Input power factor 0.95 Output power 800 WInput operation voltage (min)160 VInput operation voltage (max)280 VOutput operation voltage (min)220 VOutput operation voltage (max)240 VSurge energy rating 600 JEfficiency 88% Emergency Power Off (EPO) No Output voltage Total Harmonic Distortion (THD)3% Noise level 50 d B Crest factor 3:1 Audible alarm (s) Yes Output power capacity 1 k VASocket circuit breaker Yes ECO mode Yes Maintenance-free Yes Input frequency 40/70 Hz Battery Battery technology Sealed Lead Acid (VRLA) Battery recharge time 4 h Automatic battery test Yes Design Rack capacity 2UForm factor Rackmount LED indicators Yes Product colour Black Display LCDCertification CE, IEC 62040-1-1, IEC 62040-1-2 REACHOperational conditions Operating temperature (T-T)0
- 40 &176;CStorage temperature (T-T)-20
- 50 &176;COperating relative humidity (H-H)0
- 95% Storage relative humidity (H-H)0
- 95% Operating altitude 0
- 3000 m Non-operating altitude 0
- 14763.6 m Technical details Output frequency 50/60 Hz Sustainability certificates Ro HSWeight & dimensions Weight 11kg Width 437 mm Height 86 mm Depth 312 mm Package width 455 mm Package depth 551 mm Package height 218 mm Package weight 13.1kg Packaging data Cables included USB cable Manual Yes Software CDYes Package width 455 mm Package depth 551 mm Package height 218 mm Package weight 13.1kg Certificates Certification CE, IEC 62040-1-1, IEC 62040-1-2 REACHOther features Nominal output voltage 230 VNominal input voltage 230 VPackaging content Cables included USB cable Manual Yes Software CDYes\n\n\n\n Datasheet: https://d 5bm 31en 4blvo.cloudfront.net/uploads/pdf/mmo_65457871_1547800986_4289_14033.pdf