More From Contributor

£41.95
Up to four devices (e.g., monitor, printer, modem) are automatically switched on/off with the main device plugged into the red "master" socket. This means that you don't have to switch devices on/off individually. If consumers are switched on, a red indicator light comes on. In order to adjust the red master socket to the connected master device (main device), you can configure the switching threshold individually (min. 15 W). Integrated surge protection protects the connected devices from surges due to, for example, inductive & capacitive voltage peaks during switching, atmospheric effects & static charges. If surge protection fails, an acoustic warning is given. The additional line filter protects against high-frequency interferences from the mains. ...
Archived Product
£20.99
Suited to connecting sensors to PLC inputs. Sensor connections on same interface relay input with simple cable assignment. Bridgeable for multiple sensors/NOCs for sensors with 2 connections or when controlling via NOC BB = + (plus), A1 = single sensor/NOC output. Bridgeable for multiple sensors for sensors with 3 connections, A2 = – (minus) bridgeable for multiple sensors, A1 = single sensor output. Terminals A2, BB & 13+ are bridgeable. ...
Archived Product
£19.99
Suited to connecting actuators to PLC outputs. Actuator connections on same interface relay output with simple cable assignment. Connect operating voltage for actuators on BB – 13+ (+ on 13+). BB = bridgeable for multiple actuators. 13+ = bridgeable for multiple actuators. 14 = individual control of actuators. Terminals A1 or A2, BB & 13+ are bridgeable. ...
Archived Product
£17.99
Suited to connecting actuators to PLC outputs. Actuator connections on same interface relay output with simple cable assignment. Connect operating voltage for actuators on BB – 13+ (+ on 13+). BB = bridgeable for multiple actuators. 13+ = bridgeable for multiple actuators. 14 = individual control of actuators. Terminals A1 or A2, BB & 13+ are bridgeable. ...
Archived Product
£16.99
Universal interface relay in PLC inputs or PLC outputs for controlling actuators. Terminals A1 or A2 & 13+ bridgeable. Optional output fuse module for individual standard micro fuses (5 x 20 mm). Fuse condition is clearly visible through window. Easy to attach/exchange fuse module. Micro fuses (not included) must be acquired & attached by user. ...
Archived Product
£19.99
Universal interface relay in PLC inputs or PLC outputs for controlling actuators. Terminals A1 or A2 & 13+ bridgeable. Optional output fuse module for individual standard micro fuses (5 x 20 mm). Fuse condition is clearly visible through window. Easy to attach/exchange fuse module. Micro fuses (not included) must be acquired & attached by user. ...
Archived Product
£17.99
Universal interface relay in PLC inputs or PLC outputs for controlling actuators. Terminals A1 or A2 & 13+ bridgeable. Optional output fuse module for individual standard micro fuses (5 x 20 mm). Fuse condition is clearly visible through window. Easy to attach/exchange fuse module. Micro fuses (not included) must be acquired & attached by user. ...
Archived Product

MasterINPUT Series 39.40 Interface Relay With Optocoupler Outpu

Suited to connecting sensors to PLC inputs. Sensor connections on same interface relay input with simple cable assignment. Bridgeable for multiple sensors/NOCs for sensors with 2 connections or when controlling via NOC BB = + (plus), A1 = single sensor/NOC output. Bridgeable for multiple sensors for sensors with 3 connections, A2 = – (minus) bridgeable for multiple sensors, A1 = single sensor output. Terminals A2, BB and 13+ are bridgeable.
RIP - This product is no longer available on our network. It was last seen on 24.08.2013

This page now acts as a permanent archive for this product. Add more information using the comments box below to ensure it can still be found by future generations.

Use our search facility to see if it is available from an alternative contributor.
  • Availability: Out Of Stock
  • Supplier: Conrad
  • SKU: 506913
Availability: In Stock
£17.99

Product Description

Suited to connecting sensors to PLC inputs. Sensor connections on same interface relay input with simple cable assignment. Bridgeable for multiple sensors/NOCs for sensors with 2 connections or when controlling via NOC BB = + (plus), A1 = single sensor/NOC output. Bridgeable for multiple sensors for sensors with 3 connections, A2 = – (minus) bridgeable for multiple sensors, A1 = single sensor output. Terminals A2, BB & 13+ are bridgeable.

Reviews/Comments

Add New

Intelligent Comparison

Oooops!
We couldn't find anything!
Perhaps this product's unique.... Or perhaps we are still looking for comparisons!
Click to bump this page and we'll hurry up.

Price History

Oooops!
We couldn't find any historical pricing!

Vouchers

No voucher codes found.
Do you know a voucher code for this product or supplier? Add it to Insights for others to use.

Facebook

Jargon Buster

Cable - A series of wires bonded to form a single thread
Simple - Basic, easy no difficulty in understanding.

Supplier Information

Conrad
Conrad have been at the cutting edge of technology around the world for over 85 years. From Berlin in 1923 Conrad has expanded through the years and is now a global player in technology and consumer electronics.
Page Updated: 2013-04-27 03:03:13

Community Generated Product Tags

Oh No! The productWIKI community hasn't generated any tags for this product yet!
Menu