Universal interface relay in PLC inputs or PLC outputs for controlling actuators. Terminals A1 or A2 and 13+ bridgeable. Optional output fuse module for individual standard micro fuses (5 x 20 mm). Fuse condition is clearly visible through window. Easy to attach/exchange fuse module. Micro fuses (not included) must be acquired and attached by user.
Suited to connecting sensors to PLC inputs. Sensor connections on same interface relay input with simple cable assignment. Bridgeable for multiple sensors/NOCs for sensors with 2 connections or when controlling via NOC BB = + (plus), A1 = single sensor/NOC output. Bridgeable for multiple sensors for sensors with 3 connections, A2 = – (minus) bridgeable for multiple sensors, A1 = single sensor output. Terminals A2, BB and 13+ are bridgeable.
Suited to connecting actuators to PLC outputs. Actuator connections on same interface relay output with simple cable assignment. Connect operating voltage for actuators on BB – 13+ (+ on 13+). BB = bridgeable for multiple actuators. 13+ = bridgeable for multiple actuators. 14 = individual control of actuators. Terminals A1 or A2, BB and 13+ are bridgeable.
Universal interface relay in PLC inputs or PLC outputs for controlling actuators. Terminals A1 or A2 and 13+ bridgeable. Optional output fuse module for individual standard micro fuses (5 x 20 mm). Fuse condition is clearly visible through window. Easy to attach/exchange fuse module. Micro fuses (not included) must be acquired and attached by user.
Suited to connecting actuators to PLC outputs. Actuator connections on same interface relay output with simple cable assignment. Connect operating voltage for actuators on BB – 13+ (+ on 13+). BB = bridgeable for multiple actuators. 13+ = bridgeable for multiple actuators. 14 = individual control of actuators. Terminals A1 or A2, BB and 13+ are bridgeable.
Suited to connecting sensors to PLC inputs. Sensor connections on same interface relay input with simple cable assignment. Bridgeable for multiple sensors/NOCs for sensors with 2 connections or when controlling via NOC BB = + (plus), A1 = single sensor/NOC output. Bridgeable for multiple sensors for sensors with 3 connections, A2 = – (minus) bridgeable for multiple sensors, A1 = single sensor output. Terminals A2, BB and 13+ are bridgeable.
Universal interface relay in PLC inputs or PLC outputs for controlling actuators. Terminals A1 or A2 and 13+ bridgeable. Optional output fuse module for individual standard micro fuses (5 x 20 mm). Fuse condition is clearly visible through window. Easy to attach/exchange fuse module. Micro fuses (not included) must be acquired and attached by user.