The WT120 head transmitter converts a temperature signal in a 4 to 20 mA or 20 to 4 mA standard signal. The supply of the signal converter from the current loop. Here the output signal is linearly proportional to the input The signal converter can be completely adjusted before the assembly over the software and is immediately ready for use. When programming the software, no power supply is necessary since this is done via the programming connector.
The Universal head transmitter WT121 converts the temperature signals, or a voltage signal into a 4 to 20 mA or 20 to 4 mA standard signal. The supply of the signal converter from the current loop. Here the output signal is linearly proportional to the input The signal converter can be completely adjusted before the assembly over the software and is immediately ready for use. When programming the software, no power supply is necessary since this is done via the programming connector.
Configurable temperature measuring transducers for Pt 100, Pt 200, Pt 500, Pt 1000 and resistors 0-1 kΩ, and 0 - 4.5 Ohms. The configuration is made by DIP switches or the configuration software, over which further sensor types as well as inverting of the output signals are stopped.
The signal converter WK120 converts signals of Pt100 or a Ni100 temperature sensor in a mA standard signal. The supply of the signal converter is out of the current loop. Here the output signal is linearly proportional to the input The signal converter can be set completely before mounting with DIP switches or software, and is immediately ready for use. When programming the software, no power supply is necessary since this is via the programming connector. To mount the WK120, simply grab a hat-rail.
The measuring transducers intended for the industrial employment records the temperature with a resistance thermometer Pt 1000 in two or three-leader circuit. The fully analog signal path enables fast response times of the output at the temperature change (analog time measurement instead of digital measuring rate). This results in a low-noise and noise-immune output signal. High precision, even with small measuring range, is guaranteed by the measuring range-specific reinforcement. The assembly takes place on mounting rails for control cabinet installation. Over a DIP switch the following temperature ranges can be set: 0 - 50 °C, 0 - 60 °C, 0 - 150 °C, 0 - 200 °C, 0 - 250 °C, 0 - 300 °C, 0 - 400 °C, 0 - 500 °C, 0 - 600 °C, -20 - 80 °C, -30 - 60 °C, -30 - 70 °C, -40 - 60 °C, -50 - 50 °C.
The universal signal converter converts WZ109REG2 current / voltage signals, signals from temperature sensors and resistance signals and potentiometer signals into a standard current or voltage signal Here the output signal is linearly proportional to the input With the additional input / output, an alarm level can be issued or more WZ109REG2 to be operated in Multiplex mode on a PLC Via DIP switches or via software on the PC the device is completely stopped and is immediately ready for use. To mount the WZ109REG2, simply grab a hat-rail.
Narrow 3-way converter with galvanic isolation for Pt100. Connect via 2, 3 or 4 wire technology Output via DIP switches easily adjustable Narrow 6.2 mm wide housing. High resolution with 14 bit. Power supply via terminal connection. Simple mounting rail.
3-way converter with galvanic isolation for THERMAL ELEMENTS type S, T, J, N, C, E, R, B. Adjustable alarm output as a static relay Output via DIP switches easily adjustable Narrow 6.2 mm wide housing. High resolution with 14 bit. Power supply via terminal connection. Simple mounting rail.
The universal digital galvanic saperator WK112 galvanically separates digital signals. A damage by over-voltage, interference, or a defective sensor, controller is prevented by the galvanic separation Via DIP switch, the device is completely set and is immediately ready for use. These are the signals in the output / power supplymax. 400 Hz of input completely galvanically separated To mount the WK112, simply grab a hat-rail.